Wednesday, December 14, 2011

Hydraulic Pump Stop Operated by itself after a certain hours

There was a day, when you've got the problem, which you should not run from it, but face it wisely.

Ok2..back to the topic. Once I've face a problem with one of my offline circulation filtration pump units. This pump unit normally is operated to be used to top-up the oil quantity inside the tank when it reach at the low level and also to keep the oil inside the tank circulating through the filtration system once the whole system stop from operation.

Problem:
The pump is turned on. After around an hour, the pump was found stopped without anyone switching it off. The pump's motor is considered tripped. Try to switch it on back and keep on monitoring for next hours. The problem since repeated.

Action:
Change the filter element with new spare. Switch on back the pump and wallao.....the pump smoothly operated for continuous 8 hours.

Findings:
The filter element has clogged. Why clogged hydraulic filter element resulting tripping pump's motor. Electrical motor has certain setting on the Amps value. This Amps value act like the pressure relief valve for hydraulic system. It protects the motor from burnt, same like the pressure relief valve protecting the hydraulic system from sudden pressure peak. This amp has the connection on the load of the motor take. The clogged filter increase more blockage which will resulting higher pressure inside the pipe/line. When the pressure increased, it will also increased the work rate for the motor. Higher load will be resulting higher amp. When the amp reached to the safety limit of the motor, it will automatically cut off the supply in order to protect the motor from burn.




Case closed =)

Tuesday, June 14, 2011

Hydraulic Power Pack Producing Loud Sound

Problem:

During operation, the power pack producing super loud noise. Even though the location of the power pack is under the cellar, but the sound can be heard till top of floor and even miles away...

During the inspection time, the power pack was shut down. Try to restart the power pack. At first minutes, the sound of the pump is normal and acceptable. Then suddenly it starts to make a lot of noise + vibration. OMG! Is the pump gonna blow? LOL...Worst case, the vibration from the power pack causing the valve stand to vibrate. And one of the pipe joint fitting get loose and causing the hydraulic oil spreading all around. Yeah baby..it's shower time...lololololol...



Action:


  • Check the condition for any loosen bolts on both of hydraulic pump and electrical motor base. Loosen bolts is one of the typical reason why pumps producing high noise. Result, everything is tighten enough...
  • Check the coupling for any defect parts. OMG!. The coupling is in good condition...
  • Remove the hydraulic pump from its location. Dismantle it into the pieces. Post-mortem it. Suspected the bearing was out-of-date. The defect bearing can also resulting the pump producing loud noise. The bearing is in good condition. Take out the vane cartridge. Dismantling all the vane blade together with the springs. Check for any scratch and broken springs. Pheww..everything is in good condition...
  • Last thing, check the suction filter condition. OMG!..The filter is clogged like hell. No wonder the pump is producing a lot of noise and vibration...Why? Because the clogged filter will block some of the oil flow into the pump. Once the pump did not sucking the adequate amount of oil, the air bubbles will be produced and pump will start to suck oil and air bubbles. This situation can cause aireation to the hydraulic pump.

Conclusion:

Clogged suction filter can resulting excessive vibration and noise the hydraulic pump.... 




















CASE CLOSED..=)

Tuesday, November 2, 2010

Maintenance Philosophy

Philosophy in maintenance? huh! Really? What is the maintenance philosophy?

(Drum Roll ...........................................)



Well, neither these philosophy are consider official nor not yet it can be implement into the Maintenance Area. Hydraulic system consists of wide area such as design, analysis, maintenance and many more. Hence the maintenance of hydraulic system is one of the most crucial part to ensure the systems are at optimum condition anytime anywhere.



Ok. BAck to the future topic. What is the maintenance philosophy? (actually this is the philosophy created and faith by the writer...LOL)

There are three stooges major area. SMT.

What the heck is this SMT? Ok2...SMT are:



(drum Rolllllllllllllllllllllllll ...............)



Spare Parts

Manpower

Tools




Yeah! These 3 item is related each other and is effecting each other. However, let go deeper into this topic...



To me, the most important thing among these item are Spare Parts. Why? Because parts are the 'things' that ensuring our machine, system or whatever operate!


Example:

Imagine a lifting machine which is used to lift...... let say a box from lower level to higher place. As for the hydraulic system, normally the system will consists of hydraulic cylinder (for lifting purpose), hydraulic pump, hydraulic hoses and hydraulic control valves. These are the must-have-item in a hydraulic system to operate it.

Good maintenance practice must ensure all the parts at least have one unit to ensure any breakdown occur can be rectify in a minimum time. Let say, in worst case, the hydraulic pump did not have any spare and suddenly breakdown occur, WTF! The hydraulic system will be totally halt! The hydraulic pump is the heart of the hydraulic system! Without it fluid can't be distributed in the system....

How to seek for emergency remedy? Is there any ways to operate the system while waiting the new pump from the manufacturers/suppliers? Anything that can act like the hydraulic pump?


Heck! The answer is NO! That's why the Spare Parts is at the First Place!!

It's useless to have adequate manpower and tools without spare part(personal thought)




Number two, manpower. To execute maintenance activity, manpower is needed. Either while executing preventive, reactive or proactive maintenance (these maintenance topic will be discussed in next time), we still need the manpower. Adequate manpower will ensuring the task is carried out proper way and time.


Example:

Take above lifting machine as the sample. Same situation; the broken pump. This time the maintenance team has the spare parts and adequate, proper tools. But at the time situation take place there are only two technician in-charge out of three person in-charge during normal operation. The activity still can be carried out but it will consume a little bit more time (and increasing the machine downtime). However the situation is less worse than having no spare parts during breakdown!


But, adequate manpower is very important in maintenance activity in order to ensure the activity is smooth and tip-top!



The chosen last one, tools. Tools are important because use to remove, open, detach, attach and many more activity which is relevant. Proper and adequate tools in maintenance lead to the good time and cost management!


Example:


Still the same lifting machine with the same broken pump. This time the maintenance team is having enough spare parts and manpower are all attending(luckily there are no member suddenly need to meet the doctor and take medical leave during the breakdown occur..LOL!). They need to replace the broken pump with the new pump. While doing the activity suddenly the wrench which is needed to open the M30 size MIA (missing in action..LOL!). How can they open the bolt? What they need to do?

No worries, with a little bit of creativity, experience, skills and determination the first aid kit can be made. One way is to fabricate wrench-look-alike-yet-functioning temporarily from other materials(let say mild steel plate). Once completed, the job can be finished (yet is still consuming more time). However, this scenario can be worst as having no spare parts if the activity need some sort of special equipment/tools.





By right, these three factors need to be closely monitored in order to achieve good maintenance practice. Sometime luck can be with us, and sometime they don't.

However, if you are feeling the luck is not with you, you can have the Lucky Strike Cigar...........(ok..that's a joke actually....ok...fine..it's not funny)


Till we meet again. Buh-bye!

Tuesday, June 8, 2010

Don't Play-play with leaking!

Alright, since i have limited time, so this post will be super short yet informative!

One of the most common problem in hydraulic system is leaking. Normally took place at piping fittings connection, hydraulic cylinder hose connection fittings, hydraulic cylinder piston (normally called as inner leaking), valve connector, valve stand/block and flange packing.

Why leaking occur?

There are some reasons why leaking can occur but the popular reasons are:

- repetitive high vibration / shock at the piping.
- overheated hydraulic oil in the system.
- high contaminated / residue in the hydraulic oil.
- improper hydraulic system design


Why we must not neglecting leaking?

- high operation costing (hydraulic oil will flowing out from the piping / container through the leaking point. The higher the operation pressure, the faster oil will be drained out)....P/s: high operation cost mean high possibility to be scolded by superior....lol!

- reducing the efficiency of the hydraulic system.

- high possibility to allowed more dust, particle, to enter to the hydraulic system through the leaking point. As the result, your equipment will tear and wear faster than it supposed.

- allowing air to enter into the system which will causing cavitation. High cavitation is very dangerous for hydraulic pump. Eventually, hydraulic pumps must be filled with the hydraulic oil all the time during running. Dry running / air existence in the hydraulic pump will causing the component to damage!




So..DON'T 'PRAY-PRAY' WITH LEAKING!


Thursday, May 6, 2010

Hydraulic Cylinder Force Over Pre Set Limit

One fine morning, where the bird chirping happily, and the sunny shine nicely...


Mr.X: (reading a SMS that just arrived)

hello brother! We had problem with the cylinder hydraulic, the force on the operational side is going higher beyond preset,resulting some parts of the machine damaged. our team has been doing troubleshooting since last night...suspected EMG Valve problem- Mr. XX


Mr.X: hrmm...what happened here? (asked him once arrive at the crime-scene)

Mr.XX:well the force still go beyond the limit. We suspected the EMG problem. We already take out the EMG valve out, and service it by cleaning all the suspected dirt on the hole. We also already has keep on setting the spool..but the problem still remain unsolved..


Mr.X: well...let me ask the operator first..has you ask the electrical team to check on their system?

Mr. XX: they are checking their programming at the MCC room..

Mr. X: Alrite!

(after collecting some information and finding the root cause of the problem)

Mr. X: (thinking intensely to solve the problems)

Why do they all focusing on the EMG valve? Is it because only the cylinder are connected to the EMG Valve? But the main problem is the force overshooted from the pre set limit. EMG Valve only responsible on controlling directional, speed and steps..hrmm..suspected not only the EMG Valve problem...the main suspected problem is the PRV (Pressure Regulator Valve)..ah ha..let we try to change this first!


Mr.X: Ok my supervisor..lets change this PRV first before we try to change the EMG valve..he is the main crime suspect...mwahaha

Mr. Supervisor: Alrite...

While changing the PRV, Mr.X asking the ElectricMan on some electrical stuff




Mr. X: Yo LetricMan...want to ask something..since the problems occur after the unsuspected electricity power supply shutdown..do the any chances for the EMG Valve socket to damage due to overflow electricity after start-up?

LetricMan: Well..this can't be happen..because we had equip circuit breaker to the EMG Valve circuit in order to protect them..Let me show you...here is the circuit breaker...if the current overshoot during startup....the circuit breaker will trip and disallow the current to flow to the EMG Valve circuit..

Mr. X:i see...

After installation completion...

Mr. Supervisor: Ok..let the operator test...









After a few test run..the operator confirm the system back to normal..and the operation resume...



Problem: PRV malfunction
Cause: Suspected the PRV's spool damaged due to wear and tear
Countermeasure: Replace the PRV with a new set


CASE CLOSED